Giganet Single Phase VRLA Online Double Conversion UPS

Giganet 15kVA, 20kVA Single Phase (VRLA) UPS

Image-empty-state_edited.jpg

Key Features

  • FEATURES

  • LCD support Rack/Tower convertible design

  • N+X parallel redundancy,support maximum 4 units in parallel

  • Online double conversion with DSP control

  • Input crrent harmonic:<3%

  • Wide input voltage range:208~478Vac

  • Wide input frequency range 40~70Hz

  • Optimization battery group,the quantity of battery:30~50pcs is settable

  • Maximum charging current up to 20A (Settable)

  • Dual input source

  • Support 3/3 and 3/1 and 1/1 operation

  • Generator compatible

  • ECO mode operation for energy saving

  • Cold start

  • 50/60Hz Frequency converter mode

  • The output can meet 100% unbalanced load

  • Multiple protection function:short-circuit,overload,overheat, battery

  • overcharge and overdischarge,output low voltage and fan fault alarm

  • RS232, RS485, Parallel, Intelligent Slot (SNMP card/ Relay card (Optional)),

  • BMS (Optional),EPO port,Output port,

  • Multiple protection function: short-circuit,overload,overheat, battery

  • overcharge and overdischarge, output low voltage and fan fault alarm

  • PDU with maintenance bypass switch (Optional)

  • IEC 62133 (Cell)/IEC 62619 (Pack)/UN 38.3 (Transportation) certificate

Giganet 6kVA, 10kVA Single Phase (VRLA) UPS
(Includes SNMP Card and Rails)

Image-empty-state_edited.jpg

Key Features

  • True double-conversion

  • The rack-mounted and floor-standing tower can be convertible

  • Patented Mimic LCD of which content can be rotated according to the type of deployment

  • Digital control guarantees high reliability

  • Output receptacle control for non-critical load shedding capability

  • ECO mode operation for energy saving

  • Emergency power-off function(EPO)

  • Generator compatible

  • Communications:RS-232,USB,SNMP card(Optional), Relay card (Optional)

  • The bypass can be used when UPS is off(Set in LCD)

  • Cold start

Giganet 1kVA, 2kVA, 3kVA Single Phase (VRLA) UPS
(Includes SNMP Card and Rails)

Image-empty-state_edited.jpg

Key Features

  • True double-conversion

  • The rack-mounted and floor-standing tower can be convertible

  • Patented Mimic LCD of which content can be rotated according to the type of deployment

  • Digital control guarantees high reliability

  • Output receptacle control for non-critical load shedding capability

  • ECO mode operation for energy saving

  • Emergency power-off function(EPO)

  • Generator compatible

  • Communications:RS-232,USB,SNMP card(Optional), Relay card (Optional)

  • The bypass can be used when UPS is off(Set in LCD)

  • Cold start