Giganet Tower Type UPS
Giganet 3-Phase UPS 10-40kVA
(Includes SNMP Card)
Part Number:
GN-UPS-XXKVAX-T
Key Features
Double Conversion Online Design
High input power factor, it can be up to 0.99
3-level inverter topology, the efficiency can be up to 95.5%
Support parallel expanded operation: maximum is 8 units
Support sharing batteries for the UPS in parallel
Batteries number of each group can be selected from 30 pieces to 50 pieces
Large charging current can meet the requirement of long time backup
Output power factor is 1.0, UPS can supply power to 100% unbalance load
High adaptability for load, it can connect full inductive load or capacitive load
Power Walk In function, it can reduce the start current impact to system, and it can reduce the capacity of generator
LBS function can realize 2 independent UPS system work in synchronization, and it enhances the reliability of the system
Support USB, RS485, RS232, SNMP, dry contact card
Giganet 3-Phase UPS 10-50kVA
(Includes SNMP Card and Rails)
Part Number:
GN-UPS-XXKVA-3RT
Key Features
Double conversion online design
Input power factor correction (PFC) technology, input power factor up to 0.99
Digital signal process (DSP) makes the system more stable and reliable
Parallel cabinet is not required, it can be paralleled directly; 10~30kVA can be paralleled by 4 sets, 40~50kVA by 6 sets
LBS synchronization (40~50kVA)
Battery pack can be common connection in parallel operation
30~50 pcs batteries are settable
Suitable for complete unbalanced load
Users can set the charging current, constant current, constant voltage and floating charging three-stage charging management automatic smooth switch
Output overload, output short circuit, inverter over temperature, battery under voltage warning and battery overcharge protection
Static electronic bypass switches
DC start function
Fan intelligent speed regulation design, prolong fan life, high efficiency and energy saving
EPO (Emergency Power Off) function
LED+LCD Display
Giganet 3-Phase UPS 15-20kVA
(Includes SNMP Card and Rails)
Part Number:
GN-UPS-XXKVA-3RT
Key Features
LCD support Rack/Tower convertible design
N+X parallel redundancy,support maximum 4 units in parallel
Online double conversion with DSP control
Input crrent harmonic:<3%
Wide input voltage range:208~478Vac
Wide input frequency range 40~70Hz
Optimization battery group,the quantity of battery:30~50pcs is settable
Maximum charging current up to 20A (Settable)
Dual input source
Support 3/3 and 3/1 and 1/1 operation
Generator compatible
ECO mode operation for energy saving
Cold start
50/60Hz Frequency converter mode
The output can meet 100% unbalanced load
Multiple protection function:short-circuit,overload,overheat, battery overcharge and overdischarge,output low voltage and fan fault alarm
RS232, RS485, Parallel, Intelligent Slot (SNMP card/ Relay card (Optional)), BMS (Optional),EPO port,Output port,
Multiple protection function: short-circuit,overload,overheat, battery overcharge and overdischarge, output low voltage and fan fault alarm
PDU with maintenance bypass switch (Optional)
IEC 62133 (Cell)/IEC 62619 (Pack)/UN 38.3 (Transportation) certificate
Giganet 3-Phase UPS 200-1000kVA
(Includes SNMP Card)
Part Number:
GN-UPS-XXXKVA-TE
Key Features
Wide input voltage range 138-485Vac, UPS will derate to 40% when input voltage is below 305V
Thickened conformal coating, applicable for harsh environment such as high heat, high humidity, dust, salt spray
High input power factor, it can be up to 0.99
3-level inverter topology, the efficiency can be up to 96%
THDi<3% (100% linear load)
The UPS will work in sleeping mode when the load is very small
LBS function can realize 2 independent UPS system work in synchronization, and it enhances the reliability of the system
Power Walk In function, it can reduce the start current impact to system, and it can reduce the capacity of generator
Support parallel expanded operation: maximum is 8 units
Support sharing batteries for the UPS in parallel
Batteries number of each group can be selected from 30 pieces to 50 pieces
Output power factor is 1.0, UPS can supply power to 100% unbalanced load
High adaptability for load, it can connect full inductive load or capacitive load
With 7 inches (Standard) and 10 inches (Optional) colorful touch LCD screen
Support SNMP, RS232, RS485, Dry contact interface
Giganet 3-Phase UPS 50-200kVA
(Includes SNMP Card)
Part Number:
GN-UPS-XXXKVA-T
Key Features
Wide input voltage range 138-485Vac (Phase voltage 80-280Vac), no derating when input voltage ≥ 305Vac
High input power factor, it can be up to 0.99 3-level inverter topology, the efficiency can be up to 95.5%
Support parallel expanded operation: maximum is 8 units
Support sharing batteries for the UPS in parallel
Batteries number of each group can be selected from 30 pieces to 50 pieces
Large charging current can meet the requirement of long time backup
Output power factor is 1.0, UPS can supply power to 100% unbalance load
High adaptability for load, it can connect full inductive load or capacitive load
Power Walk In function, it can reduce the start current impact to system, and it can reduce the capacity of generator
LBS function can realize 2 independent UPS system work in synchronization, and it enhances the reliability of the system
Support USB, RS485, RS232, SNMP, dry contact card