Giganet Enviromental Monitoring System (EMS)
Giganet DCIM Integrated Touch Pad Monitor
Part Number:
GN-DCM-ITP
Key Features
Embedded installation, simple, convenient management.
Has rich interface, which can realize fast data acquisition and processing.
9.7 -inch capacitive screen, good man-machine interface and touch performance.
Front-facing camera, the camera records operator.
Manageable smart devices and temperature and humidity environment.
Feature-rich, configurable linkage alarm and SMS alarm, etc.
Giganet DCIM Mobile Monitor
Part Number:
GN-DCIM-MOB-MON
Key Features
Support for Single Phase UPS
Support monitoring of power equipment;
Support monitoring of air condition equipment;
Support monitoring of data center environment;
Support link of security system;
User friendly interface that is easy and con venient for use;
Perfect history record;
Support SNMP V2 protocol, RFC1628 MIB, XPPC MIB;
Built-in WEB server to achieve HTTP access;
Multiple compatibility of various brands and types of UPS, precision air condition, precision power distribution cabinet, generator, etc;
Built-in rechargeable battery which can be continuous running for 8 hours when power outage;
Support history events and data storage (expansion by SD card capacity);
Support to extend 8 channels of dry contact signal input(Such as smoke, water leakage, door contact, etc);
Support to extend 24 channels of temperature and humidity detection and 8 general air condition infrared control;
Support sound light alarm, SMS, E-mail alarm and SNMP Trap;
Support multiple users authority management;
Support DHCP;
Support scheduled task;
Support TELNET, WEB page configurations;
Support network upgrades, USB upgrade.
Giganet DCIM Ultra Monitor Data Centers
Part Number:
GN-DCIM-ULTRA-MON
Key Features
Highly integrated, one-stop management;
Cloud technology. WEB access, buiIdin guide function;
Embed in software, 8/S structure. system safety and reliable;
Support to monitor and control smart power devices like UPS, UPS battery,
power distribution cabinet, POU, generator, etc;
Support complete environment detect like temp. humid, smoke, leakage, gas, dust, etc;
Support monitor and control precision or split air conditioning;
Provide security system integration like CCTV, access control:
Support 10 detect neutral earth voltage, in time to find grounding danger;
Provide map mode display;
Excellent compatibility, plug and play;
Support mobile APP monitoring;
Provide multiform alarm notifications like email, SMS, telephone, sound light, broadcast, etc.
Giganet DCIM Main Monitor for Small Data Centers
Part Number:
GN-DCIM-MAIN-MON
Key Features
Support for Single Phase UPS
16 digital input terminals (0-5V TTL level); support to add-on dry contact type environment sensor;
8 analog input terminals (0 ~ 5V linear level); support to detect analog quantity such as current, voltage frequency, etc;
5 digital output terminals(12VDC / 1A), can realize the sound-light alarm and another equipment linkage; Support 20 temperature & humidity sensors;
Built-in TCP/IP network function module, support many kinds of network protocol such as SNMP V1, V2, V3, HTTP, HTTPS, DNS,
SMTP, DHCP, SNIP, SSH, SSL;
Support IPV6/IPV4;
Network mode: the LAN which is based on IP, WAN, Internet, ADSL, E1, wireless Ethernet, etc;
Safe and reliable user permission management;
Built-in optimal IP Power communication protocol, guarantee the real-time data acquisition and make full use of bandwidth;
Support multiple configuration management mode such as Telnet, Hyper
Terminal, Web browser, etc;
Supports task schedule can set UPS timing open/shutdown, battery timing discharge, etc.
Compatible with multi-brand and multi-type of UPS;
Support history data and history event record;
Built-in system clock, and support auto-reset to achieve time synchronization Support Email alarm;
Optional GSM module, support SMS query and alarm.
Giganet DCIM Mini Monitor
Part Number:
GN-DCIM-MINI-MON
Key Features
Support Single Phase UPS
Support web-based monitoring.
Monitor basic information such as current, voltage, bypass, utility power status, etc;
Multiple compatibilities for different types and brands of UPS like APC, EMERSON, EATON,DELTA etc.;
Support environment monitoring (temperature & humidity, smoke sensor, water leakage detection, etc.);
Support e-mail and sound-light alarm;
Support web visit;
Support centralized monitoring.
Support SNMP V2 protocol, RFC1628 MIB, XPPC MIB;
Built-in WEB server to achieve HTTP access;
Multiple compatibilities of various brands and types of UPS;
Support history events and data storage;
Support to extend 4 channels of dry contact signal input(Such as smoke, water leakage, door contact, etc);
Support 2 channels of relay manual control output and linkage control output;
Support to extend temperature and humidity detection and general air condition infrared control;
Support E-mail alarm and SNMP Trap;
Support multiple users authority management;
Support DHCP;
Support scheduled task;
Support TELNET, WEB page configurations;
Support network upgrade;
With SNTP synchronous clock.
Giganet DCIM Micro Monitor
Part Number:
GN-DCIM-MICRO-MON
Key Features
Support for Single Phase UPS
Support advantage encryption protocol such as HTTP, HTTPS, SSL, SSH, SNMPV1\V2c\V3;
Support telnet, supper terminal, WEB page configuration;
Compatible with multi-brand and multi-type of UPS
Support to add on 2 pieces of Temp&Humid sensors via RS422/RS485 ports;
Support SNMP trap,E-mail alarm notification;
Support IPV4/IPV6
Support scheduled task, remotely control UPS self-testing, switch on/off, battery regularly charge/discharge);
Support 50000 history events and 5000 data record;
Comprehensive event handle( including event record and notification);
Comprehensive managing function( data logs, SNTP and task schedule);
Support IPV4/IPV6;
Available to work with centralized software.